Equipment Function - 19 - VIRTUAL WINDSHIELD DEVICE RETRACT
This equipment function will configure the output to retract upon windshield detection. This is accomplished by "overriding" another output. Said another way, 'this' output will turn 'that' output off.
Output Logic
This defines for the system what "off" and "on" mean.
N/O Normally Open
When set to N/O Normally Open, the system will hold low (turn off its relay or command via communication protocol "off" to equipment) its signal while the output is at rest. Then when the system decides its time to turn the output "on", it will turn on and energize its relay, or command via communication protocol "on" to the equipment.
N/C Normally Closed
When set to N/C Normally Closed, the system will hold hi (turn on/energize its relay or command via communication protocol "on" to equipment) its signal while the output is at rest. Then when the system decides its time to turn the output "on", it will turn of and deenergize its relay, or command via communication protocol "off" to the equipment.
Include in the WetDown procedure
Enabling this (slider moved to the right/blue) will instruct this output to turn itself on upon "WetDown" request from the user. For more information regarding wet down, please see article Wet Down - What is it?
Pre Station On
This value, in inches, enables the user to specify how far before the front bumper reaches Distance To Gate this output should turn on.
Distance To Gate
This defines the distance, in inches, from the entry eye to the central point of the equipment's operational window as specified by equipment's operator manual.
Post Station Off
This value, in inches, enables the user to specify how long this output should remain on after the rear bumper of the vehicle has past Distance To Gate
Output Override Selection
Formerly "Virtual Output Selection"
This allows selection of which output to override, for retract purposes.
Comments
0 comments