Equipment Function - 25 - ENTRANCE SIGN
This equipment function enables the output to turn on when the selected wash(s) and/or Upsell(s) are about to be applied to the vehicle entering the tunnel. This output will turn off after the vehicle as left the entry eye.
Output Logic
This defines for the system what "off" and "on" mean.
N/O Normally Open
When set to N/O Normally Open, the system will hold low (turn off its relay or command via communication protocol "off" to equipment) its signal while the output is at rest. Then when the system decides its time to turn the output "on", it will turn on and energize its relay, or command via communication protocol "on" to the equipment.
N/C Normally Closed
When set to N/C Normally Closed, the system will hold hi (turn on/energize its relay or command via communication protocol "on" to equipment) its signal while the output is at rest. Then when the system decides its time to turn the output "on", it will turn of and deenergize its relay, or command via communication protocol "off" to the equipment.
Include in the WetDown procedure
Enabling this (slider moved to the right/blue) will instruct this output to turn itself on upon "WetDown" request from the user. For more information regarding wet down, please see article Wet Down - What is it?
Wash Selector
Here you may enable (slider moved to the right/blue) and/or disable (slider moved to the left/gray) which wash package(s) this output accept and fire upon receipt.
Upsell Selector
Here you may enable (slider moved to the right/blue) and/or disable (slider moved to the left/gray) which upsell(s) this output accept and fire upon receipt.
Motor Type
Motor Type determines how the Cruz Control Car Wash Controller is to fire this output.
0 - None
A motor type of "None" indicates the controller is to fire this physical output. Physical outputs are those that are designated "CRx". Motor City Wash Works offers multiple physical output configurations for purchase, up to a maximum of 128. Please consult with your sales representative for more information.
1 - TeSys
A motor type of "TeSys" indicates the controller is to fire an attached TeSys Bus Coupler motor starter via ModbusTCP communication. These are often referred to as "network driven" outputs. All Cruz Control Car Wash Controllers support 25 TeSys outputs; these are numbered output 128 through output 153.
2 - VFD
A motor type of "VFD" indicates the controller is to fire an attached variable frequency drive via ModbusTCP communication. These are often referred to as "network driven" outputs. All Cruz Control Car Wash Controllers support 85 VFD outputs; these are numbered output 154 through output 239.
3 - PLC
A motor type of "PLC" Indicates that the output interacts with another Motor City Wash Works Cruz Control enabled Device to carry out the I/O operation necessary via modbus TCP. These subsystems include but are not limited to the Dry n Shine and Glow Wash.