Equipment Function - 3 - REAR BUMPER ONLY
This output's on trigger is the rear of the vehicle. It will turn on as per Pre Station On. Once the rear of the vehicle has reached Distance To Gate, it will turn off after Post Station Off.
For a full explanation of outputs as well as a detailed description of the general configurations shared by all outputs, please reference the article Outputs.
For a detailed explanation of Asset Code, Asset Iteration and Asset System Level, please reference article Asset Codes, Asset Iterations and Asset System Levels Explained
Output Logic
This defines for the system what "off" and "on" mean.
N/O Normally Open
When set to N/O Normally Open, the system will hold low (turn off its relay or command via communication protocol "off" to equipment) its signal while the output is at rest. Then when the system decides its time to turn the output "on", it will turn on and energize its relay, or command via communication protocol "on" to the equipment.
N/C Normally Closed
When set to N/C Normally Closed, the system will hold hi (turn on/energize its relay or command via communication protocol "on" to equipment) its signal while the output is at rest. Then when the system decides its time to turn the output "on", it will turn of and deenergize its relay, or command via communication protocol "off" to the equipment.
Include in the WetDown procedure
Enabling this (slider moved to the right/blue) will instruct this output to turn itself on upon "WetDown" request from the user. For more information regarding wet down, please see article Wet Down - What is it?
ON during Anti Collision
Enabling this (slider moved to the right/blue) will instruct this output to keep itself on, if it was already on, during a collision avoidance event. For more information regarding collision avoidance events, please see article Collision Avoidance - What is it?
Restart Output Seconds
The second, as in time, marker for which this Output will delay fire to return to operation after an ESTOP. For instance, setting your first Dryer Arch Outputs all to 1 and your second Dryer Arch Outputs to 2, will delay by one second then fire the first arch then another second and fire the second arch.
Pre Station On
This value, in inches, enables the user to specify how far before the rear bumper reaches Distance To Gate this output should turn on.
Distance To Gate
This defines the distance, in inches, from the entry eye to the central point of the equipment's operational window as specified by equipment's operator manual.
Post Station Off
This value, in inches, enables the user to specify how long this output should remain on after the rear bumper of vehicle the has past Distance To Gate
Motor Type
Motor Type determines how the Cruz Control Car Wash Controller is to fire this output.
0 - None
A motor type of "None" indicates the controller is to fire this physical output. Physical outputs are those that are designated "CRx". Motor City Wash Works offers multiple physical output configurations for purchase, up to a maximum of 128. Please consult with your sales representative for more information.
1 - TeSys
A motor type of "TeSys" indicates the controller is to fire an attached TeSys Bus Coupler motor starter via ModbusTCP communication. These are often referred to as "network driven" outputs. All Cruz Control Car Wash Controllers support 25 TeSys outputs; these are numbered output 128 through output 153.
2 - VFD
A motor type of "VFD" indicates the controller is to fire an attached variable frequency drive via ModbusTCP communication. These are often referred to as "network driven" outputs. All Cruz Control Car Wash Controllers support 85 VFD outputs; these are numbered output 154 through output 239.
3 - PLC
A motor type of "PLC" Indicates that the output interacts with another Motor City Wash Works Cruz Control enabled Device to carry out the I/O operation necessary via modbus TCP. These subsystems include but are not limited to the Dry n Shine and Glow Wash.